tex-produkte-ocean.jpg

Ocean

New, independent, expressive: Ocean – the ship‘s deck collection. Attractive, animating, robust, resistant, strong. Above all, splash-resistant and therefore suitable for rooms exposed to moisture.

Abrasion Class

  • Beanspruchungsklasse 32
  • AC 4

Decor Properties

  • Antistatic
  • Ocean
  • Damp Rooms

Certificates

  • cert-ce-en-14041-2006.eps
  • cert-ibuuev
  • logo-eplf.eps
  • PEFC.tif
  • Made in Germany.tif
  • Blauer Engel emissionsarm.eps

General approvalforuse in constructionby Deutsches Institut für Bautechnik (German Institute forCivil Engineering)

  • Fraunhofer Institute for Wood Research inspection mark approval number Z 156 606 772 paper
Test Characteristics Test method
Formaldehyde emission < 0.05 ppm EN 717-1
Surface stain resistance Grade 5, no visible changes to surface EN 438-2, 15
Lightfastness ≥ Level 6 Blue Wool Scale
≥ Level 4 Grey Scale
EN ISO 105-B02
EN 20 105-A02
Resistance to cigarette embers Grade 4, no visible changes to surface EN 438-2, 18
Fire resistance Ignites with difficulty, at least Cfl-s1 EN 13501-1
Height difference between connected elements Average: ≤ 0.10 mm
max: ≤ 0.15 mm
EN 13329
Edge straightness (bend) ≤ 0.3 mm/m EN 13329
Openings between connected elements Average: ≤ 0.15 mm
max: ≤ 0.20 mm
EN 13329
Static indentation < 0.01 mm - no visible changes, Impression in test with straight steel cylinder of 11,3 mm diameter EN 433
Strength Thermal conductivity (W / (m × K)) Overall heat transfer coefficient Thermal
resistance ((m² × K) / W)
10 0.14 0.075

Product Range

Strength Lenght Width Panels per box m² / box Boxes per pallet m² / pallet
10 1376 113 8 1,244 42 52,244

Surfaces

1-STAB
1-Strip

Edges

Video - Clic-System

Installieren Sie Flash
um diesen Film zu sehen.

Installation instructions „Angle Angle Ocean“

Preparation for installation

Prior to laying, please store Kronotex flooring horizontally in its unopened packaging at room temperature for a minimum of 48 hours so that the planks have enough time to reach room temperature.

The following ambient conditions should prevail previous to, during, and three days following installation:

  • Floor surface: min. 15°C
  • Air temperature: min. 18°C
  • Humidity: 50 - 75%
  • 10_C2CFL1.jpg
  • 10_C2CFL2.jpg
  • 10_C2CFL3.jpg
  • 10_C2CFL4.jpg
  • 10_Werkzeugzubehoer.jpg
  • 12_Umrandung.jpg

Installation

  • 10_C2CFL6.jpg
  • 10_Angle_Angle_Ocean2.jpg
  • 10_Angle_Angle_Ocean3.jpg
  • 10_Angle_Angle_Ocean4.jpg
  • 10_Angle_Angle_Ocean5.jpg
  • 10_Angle_Angle_Ocean6.jpg
  • 10_Angle_Angle_Ocean7.jpg
  • 10_Angle_Angle_Ocean8.jpg
  • 10_C2CFL14.jpg
  • 10_C2CFL15.jpg
  • 10_C2CFL16.jpg
  • 10_Angle_Angle_Ocean12.jpg
  • 10_C2CFL17.jpg
  • 10_C2CFL18.jpg
  • 10_C2CFL19.jpg
  • Clic System
  • Kuechenzeile.jpg

Logo-Kronoply
powered by flycms